brainssl: bilateral U-Net for brain tumour segmentation
A residual 3D U-Net that segments glioma sub-regions in four-contrast brain MRI (FLAIR, T1, T1 with gadolinium, T2). Each encoder level can read the features of its mirror image across the brain's mid-sagittal plane, and the network was pretrained without labels by reconstructing hidden tissue from its contralateral twin, then fine-tuned on annotated scans.
Code, training pipeline and the full evaluation: https://github.com/mahdisabetkish/brainssl. Interactive results: https://mahdisabetkish.github.io/brainssl/.
Files
| File | What it is |
|---|---|
segmentation.onnx |
one sliding window: input image (N, 4, 160, 128, 128), output logits (N, 3, 160, 128, 128) |
segmentation.json |
everything around the window: crop, normalisation, window placement, blending, thresholds |
model.safetensors, config.json |
PyTorch weights for brainssl.smri.model.UNet3D |
The three output channels are whole tumour, tumour core and enhancing tumour, each through its own sigmoid; the label map is 1 oedema, 2 non-enhancing core, 3 enhancing tumour.
Use
Without Python, with the Rust binary from the repository:
brainssl-infer --ort-lib /path/to/libonnxruntime.so segment \
--model . --input scan.nii.gz --output scan_seg.nii.gz
From Python, the brainssl package reproduces the same pipeline (crop about the
midline, z-score per contrast, sliding windows with Gaussian blending, mirror
averaging).
Training data
Medical Segmentation Decathlon Task01 (BraTS 2016 and 2017 scans, CC BY-SA 4.0): pretraining on 576 scans (310 annotated scans with their labels ignored, plus the 266 released without labels), fine-tuning on the 310 annotated training scans of a fixed split. Validation and test scans were never used for training.
Evaluation
Held-out test split of 96 annotated scans, Dice (higher is better):
| Training labels | Model | WT | TC | ET |
|---|---|---|---|---|
| 100% (310 scans) | this model | 0.899 | 0.853 | 0.840 |
| 10% (31 scans) | same method | 0.885 | 0.802 | 0.802 |
| 10% (31 scans) | U-Net from scratch | 0.872 | 0.799 | 0.790 |
Limitations
Trained on skull-stripped scans registered to the SRI24 template at 1 mm, as released by the BraTS organisers; other preprocessing will need the same steps first. The mid-sagittal plane is estimated per scan, but strong midline shift from a large tumour weakens the left-right correspondence the model relies on. This is a research model and not a medical device.